During the processing of the semi-finished products and the finished products in transformer production, the newly installation transformer before using, and according to IEC and national standard, the turns ratio or voltage ratio should be tested in the circle rate. Can check the correctness of the transformer turn ratio, tap-changer condition, whether short circuit between turs and whether the transformer can parallel run. Traditional bridge method is complicated, and can’t read the data directly, and you have to make conversion, the testing results are data of one phase. Turns ratio tester of PS-BB103 type overcomes the shortcomings of traditional bridge method. The monitor adopts big screen with lattice liquid crystal, which has the function of indicating by menu, operating easily and directly. It finishes test of three-phase voltage ratio or turns ratio once, fast testing and high precision
DOWN LOAD TO PDF
Details
Tags

Read More About transformer ttr

Range0.9~10000
Accuracy±0.1%+2wrods (0.9~500)
 ±0.2%+2words (501-2000)
 ±0.5%+2words (2001-10000)
ResolutionMinimum is 0.0001
Output voltageAccording to load to adjust automatically.
Working power supplyAC220V±10%,50±1Hz
Applied temperature-10℃~40℃
Contrary humidity≤85%, no dew
SizeTTR Tester: 360*290*170(mm) Wire box:360*290*170(mm)
WeigthTester 5.9Kg wire box:5.65Kg

 

Functions Features:

 

(1).Instrument internal adopt precision three-phase inverter measurement power supply instead of the single-phase mains supply as measuring voltage, which eliminate the harmonic effect of the main voltage , more accuracy. If the working power supply is generator and its without any effect.

(2).using three-phase output voltage, improve the test speed, can measure the angle between the phases, automatically identify the transformer wiring group 0-11.

(3).Suitable for various of transformers, with the function of testing the Z type transformer rectifier transformer grounding transformer,electric furnace transformer, phase-shifting transformer, balanced

transformer,Scott transformer,Inverse Scott transformer.

(4).Using precision three-phase inverter power supply, has the high and low voltage reverse connect protection and transformer inter-turns short circuit protection, tap-changer protection and output short circuit protection functions, increase the stability of instrument.

(5).After inputting the rated parameters, can automatic measure transformer turns ratio, error and tap-changer points, especially for asymmetric tap-changer points, also can accurately test the position of the transformer tap-changer, can measure up to 99 points of tap-changer

(6).With 65K True Color Module LCD display, each operation step with English prompt, and the operation can be completed just by prompt and no need of manual.

(7).With Micro-printer ,USB and RS232 interface.

(8)With sealed water-proof and shock-proof sturdy hand-case, be suitable for field testing.

(9).Android mobile phones can pay attention to WeChat public number downloading and installing special software, connect the whole process control instrument through Bluetooth, and store the test data in a fixed format on the mobile phone, so as to facilitate data inquiry at any time.

Read More About ttr test

Read More About ttr test of power transformer

 

Video:

 

 

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us
Related News
  • Guide to Dielectric Test on Transformer Oil for Power Stability
    Guide to Dielectric Test on Transformer Oil for Power Stability
    Maintaining the electrical integrity of power transformers is critical for preventing catastrophic failures and ensuring grid stability. One of the most vital maintenance procedures is the dielectric test on transformer oil , which measures the oils ability to withstand electrical stress without breaking down. Transformer oil serves a dual purpose: acting as an electrical insulator and a cooling medium. When contaminants like moisture, carbon particles, or acids accumulate, the dielectric strength drops, increasing the risk of internal arcing. In this comprehensive guide, we will explore the methodologies, standards, and importance of testing insulating oils to ensure long-term equipment reliability.
    Detail
  • Comprehensive Guide to dga transformer oil analysis for Grid Stability
    Comprehensive Guide to dga transformer oil analysis for Grid Stability
    The Essential Guide to DGA Transformer Oil Analysis Maintaining the health of power transformers is critical for ensuring grid stability and preventing catastrophic failures. One of the most powerful diagnostic tools available to engineers is dga transformer oil analysis Dissolved Gas Analysis. By monitoring the specific gases that dissolve in insulating oil, technicians can listen to the internal condition of a transformer without taking it offline. This proactive approach allows for the detection of incipient faults, such as overheating or electrical arcing, long before they lead to a total blackout. In this guide, we will explore how DGA works
    Detail
  • Comprehensive Guide to the dga test for transformer oil
    Comprehensive Guide to the dga test for transformer oil
    Mastering the DGA Test for Transformer Oil: A Complete Guide Ensuring the reliability of high-voltage equipment is critical for power grid stability. One of the most effective diagnostic tools available is the dga test for transformer oil , which allows engineers to see inside a transformer without shutting it down. Dissolved Gas Analysis DGA monitors the concentration of specific gases that dissolve in the insulating oil, serving as an early warning system for potential failures. By identifying abnormal gas levels, operators can prevent catastrophic explosions and extend the operational lifespan of their assets. In this guide, we will explore how DGA works
    Detail

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.