EnglishEnglish

PUSH electric PS-1001B Double Opening Single Cup Insulation Oil breakdown voltage Bdv Tester

The insulating oil dielectric strength tester is our main product. PS-1001B is one of the three single-cup insulating oil dielectric strength testers produced by our company, which is more suitable for storage and outdoor double-open cover oil withstand voltage testing. The double-open cover design can effectively prevent the influence of external environmental factors on the test results.
DOWN LOAD TO PDF
Details
Tags
Selling Point Introduction

Read More About oil breakdown voltage tester

  1. 1, The instrument is controlled by a large capacity single chipmicrocomputer, and the work is stable and reliable.
  2. 2, There is a wide range watchdog circuit in the instrument toeliminate the phenomenon of death.
  3. 3, A variety of operation options, the instrument with astm d1816,astm d877 ,IEC156 three national standard methods and customoperation, can adapt to different users of a variety of choices;
  4. 4, An instrument using special glass mold for one time, prevent theoccurrence of oil spills and other interference phenomenon;
  5. 5, The unique high voltage terminal sampling design of theinstrument allows test values to directly enter the A/D converter,avoiding the errors caused by analog circuits, and making the measurement results more accurate.
  6. 6, The instrument has the functions of over current, overvoltage,shortcircuit and so on, and has very strong anti-interference ability andgood electromagnetic compatibility.
  7. 7,Portable structure, easy to move, easy to use both inside and outside.
Product Parameter Characteristics

 

Name                                

 Indicators

Output voltage                      

0~80 kV or 0-100kV

THVD                                           

<1%

Pressure rate                                

0.5~5.0 kV/s

Booster capacity                            

1.5 kVA

Measurement accuracy                    

±2%

Supply voltage                             

AC 220 V ±10%

Power frequency                          

50 Hz ±2%

Power                                         

200 w

Applicable temperature                  

0~45℃

Applicable humidity                      

<85 % RH

Width * height * depth                   

410×390×375 (mm)

Net weight                                   

~ 32 kg

 

Video

 

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us
Related News
  • Precision Guide to the Electrode Used in Potentiometric Titration
    Precision Guide to the Electrode Used in Potentiometric Titration
    Precision Measurement: The Role of the Electrode Used in Potentiometric Titration In the realm of analytical chemistry and industrial quality control, achieving absolute precision is non-negotiable. The electrode used in potentiometric titration serves as the heart of this process, converting chemical activity into a measurable electrical potential. Whether you are analyzing petroleum products, environmental water samples, or pharmaceutical compounds, the selection of the right sensor determines the accuracy of your endpoint detection. By eliminating the subjectivity of visual color indicators, potentiometric methods provide a scientific, repeatable approach to quantitative analysis. In this guide, we will explore the technical intricacies
    Detail
  • High Precision Analysis Using the Potentiometer Titrator
    High Precision Analysis Using the Potentiometer Titrator
    Precision Analysis with the Potentiometer Titrator: An Industry Overview In the realm of high-precision chemical analysis, the potentiometer titrator serves as a critical instrument for determining the concentration of identified analytes in a solution. By measuring the potential difference between two electrodes, these devices provide unmatched accuracy in volumetric analysis, particularly in the oil and petroleum industries. Whether you are monitoring fuel quality or analyzing industrial lubricants, the ability to detect the exact equivalence point is paramount. This guide explores the technical superiority, applications, and operational benefits of integrating advanced titration systems into your laboratory workflow to ensure rigorous quality control
    Detail
  • Optimize Petroleum Analysis with Pour Point Test Equipment
    Optimize Petroleum Analysis with Pour Point Test Equipment
    Optimizing Petroleum Analysis with Pour Point Test Equipment In the petrochemical and lubricant industries, understanding the low-temperature flow properties of oil is critical for operational safety and efficiency. High-quality pour point test equipment provides the precise measurements needed to determine the lowest temperature at which a liquid remains pourable. Whether dealing with lubricating oils, fuels, or hydraulic fluids, ensuring that these substances do not solidify in cold climates is essential to prevent engine failure and system blockages. This guide explores the technical nuances, industrial applications, and the importance of choosing professional-grade instrumentation for petroleum analysis.
    Detail

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.