PUSH Electrical PS-ZG120KV HV Hipot Electrical Tester DC High Voltage Generator

Dc high voltage generator adopts high frequency pulse width modulation (PWM) technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The wide temperature LCD screen adopts green back light, which enables clear display either in bright light or in darkness. High-pressure components use Dupont new filling material, making the product more stable and reliable. Products are widely used in electricity power supply departments, power transmission and transformation engineering company and preventive test of large industrial enterprises and scientific research institutes as regulated dc high voltage power supply.
DOWN LOAD TO PDF
Details
Tags
Product Selling Point Introduction

 

  1. ● Dc high voltage generator adopts high frequency PWM technology to make closed adjustment with high voltage stability, small ripple factor and fast reliable protection circuit. The generator can endure direct discharge by devices of large capacitance. It is of small size and of light weight, convenient for field use.
    ● Full range of linear smoothly adjusted voltage, with voltage regulation accuracy smaller than 0.1%; voltage measurement accuracy is 0.5%, resolution 0.1kv; Current measurement accuracy is 0.5%, the minimum resolution: control box 1µA, shock resistance current 0.1µA.
    ● The generator uses AC 220 V power supply (AC220V±10%, 50 hz±1%), the ripple factor is less than 0.5%, and can be used for all-weather at the site.
    ● High voltage multiplier uses Dupont materials for full solid encapsulation, overcoming the inconvenience brought by the air and oil filled equipment. Broad base and outer cylinder of light quality makes it stand steadily and more convenient for maintenance.
    ● 75% MOA voltage switch button, simple and convenient testing arrester.
    ● Over-voltage setting function displays the over-voltage value during regulation process; perfect protection against discharge of over-voltage, over-current and short circuit. This is the best companion for cable experiments.
    ● Perfect break line and non-zero potential start protection function protects the operator and samples at any time. This product has overall design of shock-proof control box, concise, clear panel design and voice prompt for operation.

     

Product Parameter

 

Voltage (KV)/
Current (mA)

Control Box

High-Voltage Unit

Rated Voltage

Size (mm)

Weight kg

Size (mm)

Weight kg

60/2-5

60KV

310 * 250 * 230

5kg

470 * 260 * 220

6kg

80/2-5

80KV

310 * 250 * 230

6kg

490*260*220

8kg

100/2-5

100KV

310 * 250 * 230

6kg

550*260*220

8kg

120/2-5

120KV

310 * 250 * 230

7kg

600 * 260 * 220

10kg

200/2-5

200KV

310 * 250 * 230

8kg

1000 * 280 * 270

20kg

300/2-5

300KV

310 * 250 * 230

9kg

1300 * 280 * 270

22kg

350/2-5

350KV

310 * 250 * 230

9kg

1350 * 280 * 270

23kg

output polarity

Negative polarity, no-voltage start, linear continuous adjustment

working power supply

50HZ AC220V±10%

voltage error

0.5%±2,minimum solution 0.1KV

current error

0.5%±2,minimum solution 0.1µA

ripple factor

better than 0.5%

voltage stability

Random fluctuation, when the grid changes ±10%, ≤0.5%

working manner

Interval working, less than 30 minutes under rated load

working condition

Temperature: 0-40℃, humidity: less than 90%

storage condition

Temperature: -10℃~40℃, humidity: less than 90%

altitude

Lower than 3000 m

 

Video

 

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us
Related News
  • Precision Guide to the Electrode Used in Potentiometric Titration
    Precision Guide to the Electrode Used in Potentiometric Titration
    Precision Measurement: The Role of the Electrode Used in Potentiometric Titration In the realm of analytical chemistry and industrial quality control, achieving absolute precision is non-negotiable. The electrode used in potentiometric titration serves as the heart of this process, converting chemical activity into a measurable electrical potential. Whether you are analyzing petroleum products, environmental water samples, or pharmaceutical compounds, the selection of the right sensor determines the accuracy of your endpoint detection. By eliminating the subjectivity of visual color indicators, potentiometric methods provide a scientific, repeatable approach to quantitative analysis. In this guide, we will explore the technical intricacies
    Detail
  • High Precision Analysis Using the Potentiometer Titrator
    High Precision Analysis Using the Potentiometer Titrator
    Precision Analysis with the Potentiometer Titrator: An Industry Overview In the realm of high-precision chemical analysis, the potentiometer titrator serves as a critical instrument for determining the concentration of identified analytes in a solution. By measuring the potential difference between two electrodes, these devices provide unmatched accuracy in volumetric analysis, particularly in the oil and petroleum industries. Whether you are monitoring fuel quality or analyzing industrial lubricants, the ability to detect the exact equivalence point is paramount. This guide explores the technical superiority, applications, and operational benefits of integrating advanced titration systems into your laboratory workflow to ensure rigorous quality control
    Detail
  • Optimize Petroleum Analysis with Pour Point Test Equipment
    Optimize Petroleum Analysis with Pour Point Test Equipment
    Optimizing Petroleum Analysis with Pour Point Test Equipment In the petrochemical and lubricant industries, understanding the low-temperature flow properties of oil is critical for operational safety and efficiency. High-quality pour point test equipment provides the precise measurements needed to determine the lowest temperature at which a liquid remains pourable. Whether dealing with lubricating oils, fuels, or hydraulic fluids, ensuring that these substances do not solidify in cold climates is essential to prevent engine failure and system blockages. This guide explores the technical nuances, industrial applications, and the importance of choosing professional-grade instrumentation for petroleum analysis.
    Detail

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.