PUSH Electrical PS-RG03 Capacitance Inductance Tester

This instrument is designed for the problems existing in the measurement of high-voltage shunt capacitor banks in substations, and refers to GB3983.2-1989 “High-voltage shunt capacitors”, DL/T840-2003 “Technical conditions for the use of high-voltage shunt capacitors” and JB5346-1998 ” It is specially developed according to national standards such as “Series Reactors”, mainly for the measurement of high-voltage parallel capacitor banks and reactors of reactive power compensation devices.
DOWN LOAD TO PDF
Details
Tags
Product Selling Point Introduction

 

  1. 1. This instrument can measure the single capacitance of a group of parallel capacitors without removing the wires (both single-phase capacitance and three-phase capacitance can be measured). kind of use.
    2. During the measurement, the instrument can display the measured capacitance value or inductance value, and can also display the measured voltage, current, power, frequency, impedance, phase angle and other data;
    3. The instrument adopts a 7.0-inch 1024×600 high-definition screen, touch operation, clear observation during the day and night, Chinese menu prompts, easy to operate.
    4. The instrument has built-in large-capacity non-volatile memory: it can store 200 sets of measurement data. The instrument is equipped with a U-disk interface, which can store any group of measurement data (limited by the capacity of the U-disk).
    5. The instrument has built-in high-precision real-time clock function: date and time calibration can be performed.
    6. The instrument comes with a high-speed micro thermal printer: it can print measurement and historical data.

 

Product Parameter 

 

Test voltage

AC 100V ±10%, 50Hz

AC 40V±10%, 50Hz

AC 10V±10%, 50Hz

AC 1V±10%, 50Hz

Measuring range and accuracy

Measurable capacitance range

0.1uF~6000uF ±(reading 1%+0.01uF)

Measurable inductance range

50uH ~20H ±(reading 3%+0.05uH)

Measurable current range

5mA ~ 2A ±(3% of reading + 0.05mA)

Measurable resistance range

20mΩ~20kΩ ±(reading 3%+0.1mΩ)

Dimensions

365mm×285mm×170mm

Ambient temperature

-20℃~40℃

Ambient humidity

≤85%RH

Working power

AC220V±10%, 50±1Hz

 

Video

 

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us
Related News
  • Guide to Dielectric Test on Transformer Oil for Power Stability
    Guide to Dielectric Test on Transformer Oil for Power Stability
    Maintaining the electrical integrity of power transformers is critical for preventing catastrophic failures and ensuring grid stability. One of the most vital maintenance procedures is the dielectric test on transformer oil , which measures the oils ability to withstand electrical stress without breaking down. Transformer oil serves a dual purpose: acting as an electrical insulator and a cooling medium. When contaminants like moisture, carbon particles, or acids accumulate, the dielectric strength drops, increasing the risk of internal arcing. In this comprehensive guide, we will explore the methodologies, standards, and importance of testing insulating oils to ensure long-term equipment reliability.
    Detail
  • Comprehensive Guide to dga transformer oil analysis for Grid Stability
    Comprehensive Guide to dga transformer oil analysis for Grid Stability
    The Essential Guide to DGA Transformer Oil Analysis Maintaining the health of power transformers is critical for ensuring grid stability and preventing catastrophic failures. One of the most powerful diagnostic tools available to engineers is dga transformer oil analysis Dissolved Gas Analysis. By monitoring the specific gases that dissolve in insulating oil, technicians can listen to the internal condition of a transformer without taking it offline. This proactive approach allows for the detection of incipient faults, such as overheating or electrical arcing, long before they lead to a total blackout. In this guide, we will explore how DGA works
    Detail
  • Comprehensive Guide to the dga test for transformer oil
    Comprehensive Guide to the dga test for transformer oil
    Mastering the DGA Test for Transformer Oil: A Complete Guide Ensuring the reliability of high-voltage equipment is critical for power grid stability. One of the most effective diagnostic tools available is the dga test for transformer oil , which allows engineers to see inside a transformer without shutting it down. Dissolved Gas Analysis DGA monitors the concentration of specific gases that dissolve in the insulating oil, serving as an early warning system for potential failures. By identifying abnormal gas levels, operators can prevent catastrophic explosions and extend the operational lifespan of their assets. In this guide, we will explore how DGA works
    Detail

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.