EnglishEnglish

PUSH Electrical PS-DD3D Fully Automatic High-Precision Titrator Potentiometric titrator

Application field: used for quality testing or scientific teaching in many industries such as medicine, food, geochemistry, petrochemical, daily chemical, agriculture, environmental protection, water treatment and so on.
DOWN LOAD TO PDF
Details
Tags
Product Selling Point Introduction

 

  1. ●Choose different electrodes for acid-base titration, redox titration, complexometric titration, silver volume titration, ion concentration determination and other experiments
    ●With dynamic titration, equivalent titration, pH endpoint titration, pH measurement and other measurement modes.
    ●Statistical analysis of titration results, including mean, standard deviation, relative standard deviation, etc.
    ●Split design, independent mixing table.
    ●Has simple people login design.
    ●The device has 20 methods and 100 result stores.
    ●Can be connected to a PC workstation for data transfer.
    ●The quality of the instrument is reliable, the failure rate of the instrument is extremely low, and the service life is more than ten years.
    ●The results have high accuracy and can meet the requirements of pharmacopoeia calibration, sample repeatability and GB/T 601-2016 “chemical reagents – preparation of standard titration solutions”.
    ●It can be printed out, and the titration result report can be output in the format required by GLP/GMP, including laboratory, experimental time, experimental personnel, sample name, titration curve, raw data and other information.
    ●Process data and curve printing can be selected.
    ●The burette can be disassembled and replaced to meet the requirements of using different burettes for experiments with different titrants, and avoid using the same buret to contaminate reagents and cause deviations in results. The actual accuracy of the burette can reach ±10uL/10mL.

 

Product Parameter 

 

Accuracy

±0.1%

Precision

≤0.1%

Burette installation method

Tool-free replacement

Burette resolution

1/20000

Burette accuracy

±10μL(10 mL)

Burette addition speed

1~99 mL /min

Measuring range

±2400 mV / ±20Ph

Resolution

0.01 mV / 0.001 pH

Indication error

±0.03 %FS / 0.005 pH

Indication repeatability

≤0.25 % / 0.002 pH

Input current

≤1×10-12 A

Input impedance

≥3×1012 Ω

Temperature and humidity measurement range

0~125℃,10~85%RH

Temperature and humidity resolution

0.1℃,1% RH

Temperature and humidity measurement error

±0.3℃,±5% RH

Titration mode

Dynamic titration, equivalent titration, endpoint titration, manual titration

Measurement method

pH, Potential, Ion Concentration, Temperature

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us
Related News
  • Guide to Dielectric Test on Transformer Oil for Power Stability
    Guide to Dielectric Test on Transformer Oil for Power Stability
    Maintaining the electrical integrity of power transformers is critical for preventing catastrophic failures and ensuring grid stability. One of the most vital maintenance procedures is the dielectric test on transformer oil , which measures the oils ability to withstand electrical stress without breaking down. Transformer oil serves a dual purpose: acting as an electrical insulator and a cooling medium. When contaminants like moisture, carbon particles, or acids accumulate, the dielectric strength drops, increasing the risk of internal arcing. In this comprehensive guide, we will explore the methodologies, standards, and importance of testing insulating oils to ensure long-term equipment reliability.
    Detail
  • Comprehensive Guide to dga transformer oil analysis for Grid Stability
    Comprehensive Guide to dga transformer oil analysis for Grid Stability
    The Essential Guide to DGA Transformer Oil Analysis Maintaining the health of power transformers is critical for ensuring grid stability and preventing catastrophic failures. One of the most powerful diagnostic tools available to engineers is dga transformer oil analysis Dissolved Gas Analysis. By monitoring the specific gases that dissolve in insulating oil, technicians can listen to the internal condition of a transformer without taking it offline. This proactive approach allows for the detection of incipient faults, such as overheating or electrical arcing, long before they lead to a total blackout. In this guide, we will explore how DGA works
    Detail
  • Comprehensive Guide to the dga test for transformer oil
    Comprehensive Guide to the dga test for transformer oil
    Mastering the DGA Test for Transformer Oil: A Complete Guide Ensuring the reliability of high-voltage equipment is critical for power grid stability. One of the most effective diagnostic tools available is the dga test for transformer oil , which allows engineers to see inside a transformer without shutting it down. Dissolved Gas Analysis DGA monitors the concentration of specific gases that dissolve in the insulating oil, serving as an early warning system for potential failures. By identifying abnormal gas levels, operators can prevent catastrophic explosions and extend the operational lifespan of their assets. In this guide, we will explore how DGA works
    Detail

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.