English


The PUSH Electrical PS-YC115 On-Load Tap-Changer (OLTC) Tester is a professional-grade diagnostic instrument engineered for the rigorous evaluation of tap-changers in power transformers. By analyzing transition resistance and switching time, this high-precision device ensures the operational reliability of critical power transmission and distribution infrastructure, preventing catastrophic failures through proactive health monitoring.
Combining a lightweight portable design with high-output current capabilities, the PS-YC115 supports a wide range of transformer configurations, including YN, Y, and △-types. With its intuitive 7-inch LCD interface and automated waveform adjustment, it streamlines the commissioning, maintenance, and troubleshooting processes for utility companies and power system operators worldwide.
| Output Current | 2.0A, 1.0A, 0.5A, 0.2A | Open Circuit Voltage | 24V |
|---|---|---|---|
| Transition Resistance | 0.3Ω~5Ω(2.0A) / 1Ω~20Ω(1.0A) / 5Ω~40Ω(0.5A) / 20Ω~100Ω(0.2A) | Transition Time Range | 0~320ms |
| Resistance Accuracy | ±(5% reading ± 0.1Ω) | Time Accuracy | ±(0.1% reading ± 0.2ms) |
| Sampling Rate | 20kHz | Data Storage | Local storage (up to 500 sets) |
| Operating Temp/Humid | -10℃~50℃ / ≤85%RH | Working Power | AC220V±10%, 50±1Hz |
Equipped with a perfect protection circuit and strong reliability to ensure safety during high-current testing.
Automatically adjusts resistance, time, and amplitude based on sampled values for real-time accuracy.
Directly tests YN, Y, and △-type transformers with resistance values displayed without complex conversion.
High-visibility screen designed for effortless operation in demanding field environments.
Versatile capability allowing measurements to be performed with or without the winding connected.
Internal memory automatically saves up to 500 sets of test data for comprehensive historical analysis.
Identify potential deteriorations in tap-changers before they escalate into major equipment failures.
Verify proper alignment and switching smoothness between tap positions during transformer installation.
Conduct comprehensive electrical evaluations to quickly pinpoint malfunctions in the OLTC mechanism.
Reduce the risk of unplanned outages by ensuring stable voltage regulation through verified switching.
Ensure adherence to industry standards with documented periodic testing and performance logs.
Optimize onsite workflows with a lightweight host and intuitive graphical user interface.
| Evaluation Metric | Traditional Manual Testing | PS-YC115 Automated Testing |
|---|---|---|
| Diagnosis Time | High (Hours/Days) | Low (Minutes) |
| Data Accuracy | Prone to Human Error | High-Precision Digital (20kHz) |
| Equipment Downtime | Extended for Troubleshooting | Minimized via Rapid Analysis |
| Risk of Failure | Higher (Reactive Maintenance) | Lower (Preventive Maintenance) |
| Labor Costs | High (Specialized Manual Work) | Reduced (Simplified Operation) |
The primary purpose is to evaluate the electrical characteristics and mechanical functionality of tap-changers in power transformers, specifically measuring transition resistance and time to ensure safe voltage regulation without interrupting power.
Yes, it is designed to test YN, Y, and △-type transformers, providing direct resistance value displays without the need for manual conversion calculations.
The instrument incorporates a specialized protection circuit and robust safety mechanisms to prevent equipment damage and ensure operator safety during testing procedures.
Yes, it features internal local storage capable of automatically saving up to 500 sets of test data for future analysis and reporting.
Measuring transition resistance helps identify worn contacts or poor connections within the tap-changer, which could lead to overheating and potential transformer failure.
The PS-YC115 features a high sampling rate of 20kHz, allowing for precise capture of fast transition waveforms and accurate time measurements.