EnglishEnglish

PSKF106V1 Volumetric Trace Moisture Tester China Factory Suppliers

Looking for reliable China suppliers? Our factory provides the PS-KF106V1 automatic Karl Fischer moisture analyzer, a high-precision instrument using volumetric titration for rapid water content measurement. Compliant with ASTM, GB6238, and GB11146 standards for professional research and production.
DOWN LOAD TO PDF
Details
Tags

The PUSH Electrical PS-KF106V1 Volumetric Trace Moisture Tester is a high-precision analytical instrument designed for the rapid and accurate determination of water content in a wide array of samples. Engineered for efficiency, this automatic Karl Fischer moisture analyzer leverages advanced electrode polarization voltage to optimize titration speeds, ensuring professional-grade results in a fraction of the traditional time.

Built for versatility and reliability, the PS-KF106V1 features a fully enclosed piping system to protect operators from toxic gases and prevent environmental moisture interference. From pharmaceutical labs to petrochemical refineries, this instrument provides the critical precision needed for quality control across industries including food and beverage, cosmetics, and organic chemical synthesis.

Detailed Parameters

Measurement Range30ppm-100% (H2O mass fraction) Resolution0.01ml
Titration Repeatability≤0.01 Linear Correlation Coeff.≥0.998
Capacity Error≤±0.002 Burette CapacityGreater than 25ml
Sensitivity10-6A Titration MethodVolumetric Trace Moisture
Display TypeHigh-brightness Digital Tube System DesignFully Enclosed Liquid Path

Key Advantages

Superior Corrosion Resistance

The entire liquid path is constructed from specialized materials to ensure long-term continuous operation and durability against corrosive reagents.

Accelerated Titration Speed

Equipped with an accelerated dripping function using electrode polarization voltage, reducing measurement time to just tens of seconds.

Precise End-Point Detection

Uses polarization voltage to accurately judge the reaction end point and automatically terminate titration for maximum reliability.

Intuitive Monitoring

Integrated ammeter and high-brightness digital display make the titration process intuitive and the readings clear at a glance.

Environmental Safety

A fully enclosed piping system prevents the escape of toxic gases and blocks environmental moisture infiltration for pure results.

Universal Reagent Compatibility

Adopts special reagent bottle connectors, supporting both standard pyridine and pyridine-free reagents for flexible lab requirements.

Product Gallery

Management Platforms

Automated Workflow

Integrated controls for solvent inhalation, measurement, and waste liquid discharge via simple function keys.

Rapid Calibration

High linear correlation coefficient (≥0.998) ensuring fast and accurate calibration across wide ranges.

Real-time Alarms

Instant end-point alarm notifications ensure no over-titration and precise sampling every time.

Safety Interruption

Quick-stop capability allows operators to immediately interrupt and restart operations if an error occurs.

Easy Maintenance

Standard solvent bottle cap connectors allow for rapid and effortless replacement of consumables.

Low-Noise Operation

Optimized enclosed design ensures smooth, quiet running, improving the laboratory working environment.

Investment Return Comparison

MetricTraditional Manual KFPS-KF106V1 Automatic
Measurement Time15-30 MinutesTens of Seconds
Human Error RiskHigh (Manual Reading)Ultra-Low (Digitalized)
Reagent WasteSignificantOptimized / Minimal
Operational SafetyOpen System / ExposureFully Enclosed / Safe
Throughput/DayLow VolumeHigh-Volume Industrial

Frequently Asked Questions

Q: What is the main advantage of the volumetric trace moisture tester over other methods?

The volumetric method is ideal for samples with relatively high water content, providing faster results and high precision through chemical titration compared to oven-drying methods.

Q: Can the PS-KF106V1 be used with pyridine-free reagents?

Yes, the instrument is designed with special reagent bottle connectors that are compatible with both standard pyridine and pyridine-free reagents.

Q: How does the electrode polarization voltage improve the testing process?

It automatically controls the dripping speed and identifies the exact reaction end point, significantly reducing testing time while increasing accuracy.

Q: Which industries typically use these moisture analyzers?

They are essential in pharmaceuticals, petrochemicals, organic/inorganic chemicals, food and beverage, and cosmetics for quality control.

Q: Is the instrument safe for operators regarding toxic reagent fumes?

Absolutely. The PS-KF106V1 features a fully enclosed piping system specifically designed to prevent the escape of toxic gases into the lab air.

Q: What is the measurement range for this specific model?

The PS-KF106V1 offers a wide measurement range from 30ppm up to 100% H2O mass fraction, catering to both trace and high-moisture samples.

Ready to Enhance Your Laboratory Precision?

Contact Us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us
Related News
  • Precision Guide to the Electrode Used in Potentiometric Titration
    Precision Guide to the Electrode Used in Potentiometric Titration
    Precision Measurement: The Role of the Electrode Used in Potentiometric Titration In the realm of analytical chemistry and industrial quality control, achieving absolute precision is non-negotiable. The electrode used in potentiometric titration serves as the heart of this process, converting chemical activity into a measurable electrical potential. Whether you are analyzing petroleum products, environmental water samples, or pharmaceutical compounds, the selection of the right sensor determines the accuracy of your endpoint detection. By eliminating the subjectivity of visual color indicators, potentiometric methods provide a scientific, repeatable approach to quantitative analysis. In this guide, we will explore the technical intricacies
    Detail
  • High Precision Analysis Using the Potentiometer Titrator
    High Precision Analysis Using the Potentiometer Titrator
    Precision Analysis with the Potentiometer Titrator: An Industry Overview In the realm of high-precision chemical analysis, the potentiometer titrator serves as a critical instrument for determining the concentration of identified analytes in a solution. By measuring the potential difference between two electrodes, these devices provide unmatched accuracy in volumetric analysis, particularly in the oil and petroleum industries. Whether you are monitoring fuel quality or analyzing industrial lubricants, the ability to detect the exact equivalence point is paramount. This guide explores the technical superiority, applications, and operational benefits of integrating advanced titration systems into your laboratory workflow to ensure rigorous quality control
    Detail
  • Optimize Petroleum Analysis with Pour Point Test Equipment
    Optimize Petroleum Analysis with Pour Point Test Equipment
    Optimizing Petroleum Analysis with Pour Point Test Equipment In the petrochemical and lubricant industries, understanding the low-temperature flow properties of oil is critical for operational safety and efficiency. High-quality pour point test equipment provides the precise measurements needed to determine the lowest temperature at which a liquid remains pourable. Whether dealing with lubricating oils, fuels, or hydraulic fluids, ensuring that these substances do not solidify in cold climates is essential to prevent engine failure and system blockages. This guide explores the technical nuances, industrial applications, and the importance of choosing professional-grade instrumentation for petroleum analysis.
    Detail

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.