High Purity PS300 Hydrogen Generator Factory Suppliers in China

Looking for reliable PS-300 High Purity Hydrogen Generator factory suppliers in China? Our system delivers 99.999 purity hydrogen with a -56C dew point, utilizing advanced fuzzy control for unmatched pressure stability and extended GC instrument lifetime.
DOWN LOAD TO PDF
Details
Tags

The PS-300 Hydrogen Generator is a high-precision gas supply system specifically engineered for Gas Chromatography (GC) test kits. By integrating advanced electrolytic technology with a specialized program-controlled chip, it provides a continuous, stable, and ultra-pure hydrogen stream, eliminating the logistical risks and costs associated with high-pressure gas cylinders.

Designed for rigorous laboratory environments, this instrument ensures exceptional gas quality with a purity of 99.999% and a dew point temperature as low as -56℃. Whether used for continuous operation or intermittent testing, the PS-300 delivers a reliable flow of carrier gas, making it an essential component for precision analytical chemistry and environmental monitoring.

Detailed Parameters

Hydrogen Purity99.999% Hydrogen Flow0-300ml/min
Output Pressure0-4Kg/cm² (approx. 0.4Mpa) Power Supply220V±10%, 50HZ
Consumption Power150W Ambient Temperature1-40℃
Relative HumidityStandard Laboratory Range Net WeightAbout 10Kg
Outer Dimensions360×200×260mm Control SystemSpecialized Program Chip

Key Advantages

Intelligent Program Control

Equipped with a specialized chip for fully automated constant voltage, current, and flow adjustment (0-300ml/min).

Ultra-Low Humidity

Utilizes film separating techniques and multi-polar absorption to reach a dew point temperature of -56℃.

High Purity Output

Delivers 99.999% pure hydrogen, ensuring the highest accuracy for Gas Chromatography analysis.

Simplified Operation

One-switch activation allows for seamless continuous or interval use without gas attenuation.

Real-time Monitoring

Integrated digital flow indicators and pressure gauges for precise system oversight.

Enhanced Safety

Built-in sensitive safety devices ensure reliable operation and protect the laboratory environment.

Product Gallery

Management Platforms

Gas Flow Control

Precision adjustment of hydrogen output from 0 to 300ml/min via program control.

Purity Management

Advanced electrolysis and purification to maintain a consistent 99.999% purity level.

Humidity Control

Integrated de-humidity devices maintaining a dew point of -56℃ for dry gas output.

Pressure Regulation

Stable output pressure up to 0.4Mpa with real-time pressure indication.

Solution Monitoring

Upper and lower limit indicators for the electrolytic solution to ensure uptime.

Safety Oversight

Highly sensitive safety mechanisms to prevent leaks and overpressure events.

Investment Return Comparison

MetricTraditional Gas CylinderPS-300 Hydrogen Generator
Gas Supply CostRecurring rental and refill feesOne-time investment, low energy cost
Safety RiskHigh pressure explosive hazardLow pressure, on-demand production
Gas PurityVariable by supplier/batchConstant 99.999% High Purity
Labor EffortFrequent cylinder replacementAutomatic, switch-on operation
Space RequiredLarge storage for cylindersCompact desktop footprint

Frequently Asked Questions

Q: How does the PS-300 maintain such high hydrogen purity?

The PS-300 uses high-efficiency electrolysis combined with a specialized purification tube and a multi-polar absorption system to ensure the hydrogen reaches 99.999% purity.

Q: Is the PS-300 compatible with all Gas Chromatography (GC) systems?

Yes, it is designed as a universal carrier gas source for GC test kits, providing a stable flow and pressure compatible with most standard analytical instruments.

Q: How often does the electrolytic solution need to be replaced?

Replacement frequency depends on usage volume. The unit features upper and lower limit indicators to notify the user exactly when the solution level is low.

Q: What safety features are included to prevent hydrogen leaks?

The system is equipped with sensitive safety devices and a low-pressure output design (max 0.4Mpa), significantly reducing the risks associated with high-pressure gas.

Q: Can the hydrogen flow be adjusted manually?

The flow is managed by a specialized program chip, allowing for automatic and stable adjustment within the 0-300ml/min range to meet your specific test requirements.

Q: Does this generator require professional installation?

The PS-300 is designed for easy operation; simply connect the power supply and the outlet port to your instrument to begin hydrogen production.

Ready to upgrade your laboratory gas supply?

Contact Us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us
Related News
  • Precision Guide to the Electrode Used in Potentiometric Titration
    Precision Guide to the Electrode Used in Potentiometric Titration
    Precision Measurement: The Role of the Electrode Used in Potentiometric Titration In the realm of analytical chemistry and industrial quality control, achieving absolute precision is non-negotiable. The electrode used in potentiometric titration serves as the heart of this process, converting chemical activity into a measurable electrical potential. Whether you are analyzing petroleum products, environmental water samples, or pharmaceutical compounds, the selection of the right sensor determines the accuracy of your endpoint detection. By eliminating the subjectivity of visual color indicators, potentiometric methods provide a scientific, repeatable approach to quantitative analysis. In this guide, we will explore the technical intricacies
    Detail
  • High Precision Analysis Using the Potentiometer Titrator
    High Precision Analysis Using the Potentiometer Titrator
    Precision Analysis with the Potentiometer Titrator: An Industry Overview In the realm of high-precision chemical analysis, the potentiometer titrator serves as a critical instrument for determining the concentration of identified analytes in a solution. By measuring the potential difference between two electrodes, these devices provide unmatched accuracy in volumetric analysis, particularly in the oil and petroleum industries. Whether you are monitoring fuel quality or analyzing industrial lubricants, the ability to detect the exact equivalence point is paramount. This guide explores the technical superiority, applications, and operational benefits of integrating advanced titration systems into your laboratory workflow to ensure rigorous quality control
    Detail
  • Optimize Petroleum Analysis with Pour Point Test Equipment
    Optimize Petroleum Analysis with Pour Point Test Equipment
    Optimizing Petroleum Analysis with Pour Point Test Equipment In the petrochemical and lubricant industries, understanding the low-temperature flow properties of oil is critical for operational safety and efficiency. High-quality pour point test equipment provides the precise measurements needed to determine the lowest temperature at which a liquid remains pourable. Whether dealing with lubricating oils, fuels, or hydraulic fluids, ensuring that these substances do not solidify in cold climates is essential to prevent engine failure and system blockages. This guide explores the technical nuances, industrial applications, and the importance of choosing professional-grade instrumentation for petroleum analysis.
    Detail

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.