EnglishEnglish

PS1006 Insulation Oil Bdv Tester China Factory and Professional Suppliers

Looking for reliable China suppliers? Our factory provides the PS-1006 six-cup insulating oil dielectric strength tester. Compliant with ASTM D1816 and ASTM D877 standards, it tests six samples simultaneously with high accuracy using flat, spherical, or hemispherical electrodes.
DOWN LOAD TO PDF
Details
Tags

The PS-1006 Six Cup Insulation Oil Bdv Tester is a professional-grade breakdown voltage instrument engineered for high-precision testing of insulating oils. Utilizing a sophisticated six-cup configuration, this device ensures exceptional consistency and reliability in determining the dielectric strength of transformer oils and other industrial insulating fluids, meeting stringent electrical safety standards.

Designed for the modern electrical laboratory, the PS-1006 integrates advanced CPU and PLC control systems to automate complex testing sequences. From voltage boosting and stirring to data calculation and storage, the instrument minimizes human error and optimizes workflow efficiency, providing operators with a stable, safe, and highly accurate diagnostic tool for power system maintenance.

Detailed Parameters

Output Voltage0~80 kV (Adjustable up to 100KV) THVD<1%
Pressure Rate0.5~5.0 kV/s Booster Capacity1.5 kVA
Measurement Accuracy±2% Supply VoltageAC 220 V ±10%
Power Frequency50 Hz ±2% Power Consumption200 W
Operating Temp/Humidity0~45℃ / <85 % RH Dimensions (WHD)770675760 (mm)

Key Advantages

Enhanced Safety

Equipped with overvoltage, overcurrent, limit, and earthing alarms to ensure maximum operator protection during high-voltage tests.

Fully Automated

Automatically handles boosting, holding, stirring, static settings, and result calculation for seamless operation.

Precision Control

Unique waveform setting functions eliminate harmonic interference, ensuring highly accurate breakdown voltage measurements.

Intuitive Interface

Features a 5.4-inch LCD display with a user-friendly menu, integrated clock, and real-time temperature/humidity monitoring.

Industrial Stability

Powered by high-performance CPU and PLC architecture to guarantee long-term stability and instrument reliability.

Flexible Connectivity

Supports RS232, USB, and Bluetooth wireless transmission for effortless data transfer to computers.

Product Gallery

Management Platforms

Auto-Save System

Integrated power-outage protection automatically saves test results to prevent data loss.

Intelligent Calibration

Precise voltage control with adjustable output up to 100KV for diverse oil grade requirements.

Safety Monitoring

Real-time earthing and over-limit alerts provide immediate notification of abnormal conditions.

Environmental Tracking

On-screen temperature and humidity tracking ensures test environment compliance.

Wireless Sync

Bluetooth integration allows for mobile monitoring and rapid report generation.

Data Export

Dual RS232 and USB ports facilitate seamless integration with laboratory LIMS software.

Investment Return Comparison

Evaluation MetricManual TestingPS-1006 Automation
Testing SpeedSlow / High LaborRapid / Fully Auto
Data AccuracySubject to ErrorHigh (±2% Precision)
Safety RiskModerate RiskLow (Multi-Alarm Sys)
Data LoggingManual RecordingAuto-Save & Bluetooth
Operational CostHigh Labor CostLow Maintenance Cost

Frequently Asked Questions

Q: What is the primary purpose of an Oil Bdv Tester in power systems?

The Oil Breakdown Voltage (Bdv) tester measures the dielectric strength of insulating oils. It determines the maximum voltage the oil can withstand before electrical breakdown occurs, which is critical for assessing the health of transformers and circuit breakers.

Q: How does the PS-1006 handle harmonic wave interference?

The PS-1006 features a unique waveform setting function specifically designed to eliminate the interference of harmonic waves, ensuring that the breakdown voltage measurement is accurate and not skewed by electrical noise.

Q: Is the data stored if there is a sudden power outage?

Yes, the device is equipped with a power-outage protection function that automatically saves all current test results, preventing data loss and reducing the need for re-testing.

Q: What communication interfaces are available for data export?

The PS-1006 provides a comprehensive suite of connectivity options, including RS232, USB ports, and Bluetooth wireless transmission for convenient data transfer to a computer.

Q: Can the output voltage be adjusted for different oil standards?

Absolutely. The output voltage ranges from 0 to 80 kV and can be specifically set up to 100 kV to meet various international standards and specific industrial requirements.

Q: What safety features protect the operator from high voltage?

The instrument incorporates a comprehensive safety system including overvoltage alarms, overcurrent protection, limit alarms, and a dedicated earthing alarm to protect personnel from electrical hazards.

Request a Technical Quote for PS-1006 Oil Tester

Contact Us

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.


Write your message here and send it to us
Related News
  • Precision Guide to the Electrode Used in Potentiometric Titration
    Precision Guide to the Electrode Used in Potentiometric Titration
    Precision Measurement: The Role of the Electrode Used in Potentiometric Titration In the realm of analytical chemistry and industrial quality control, achieving absolute precision is non-negotiable. The electrode used in potentiometric titration serves as the heart of this process, converting chemical activity into a measurable electrical potential. Whether you are analyzing petroleum products, environmental water samples, or pharmaceutical compounds, the selection of the right sensor determines the accuracy of your endpoint detection. By eliminating the subjectivity of visual color indicators, potentiometric methods provide a scientific, repeatable approach to quantitative analysis. In this guide, we will explore the technical intricacies
    Detail
  • High Precision Analysis Using the Potentiometer Titrator
    High Precision Analysis Using the Potentiometer Titrator
    Precision Analysis with the Potentiometer Titrator: An Industry Overview In the realm of high-precision chemical analysis, the potentiometer titrator serves as a critical instrument for determining the concentration of identified analytes in a solution. By measuring the potential difference between two electrodes, these devices provide unmatched accuracy in volumetric analysis, particularly in the oil and petroleum industries. Whether you are monitoring fuel quality or analyzing industrial lubricants, the ability to detect the exact equivalence point is paramount. This guide explores the technical superiority, applications, and operational benefits of integrating advanced titration systems into your laboratory workflow to ensure rigorous quality control
    Detail
  • Optimize Petroleum Analysis with Pour Point Test Equipment
    Optimize Petroleum Analysis with Pour Point Test Equipment
    Optimizing Petroleum Analysis with Pour Point Test Equipment In the petrochemical and lubricant industries, understanding the low-temperature flow properties of oil is critical for operational safety and efficiency. High-quality pour point test equipment provides the precise measurements needed to determine the lowest temperature at which a liquid remains pourable. Whether dealing with lubricating oils, fuels, or hydraulic fluids, ensuring that these substances do not solidify in cold climates is essential to prevent engine failure and system blockages. This guide explores the technical nuances, industrial applications, and the importance of choosing professional-grade instrumentation for petroleum analysis.
    Detail

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.